TL;DR: OT/IT network segmentation for manufacturers places firewall-enforced boundaries between your office network and your production network, which can keep an office-side ransomware event from automatically stopping the plant. A mid-sized plant needs four zones (the business network, a controlled boundary, plant-floor supervisory systems and production cells), and a VLAN (a label that groups devices on a switch) is not enough without firewall rules between VLANs. TechProComp recommends starting at the office-to-plant boundary, then settling ten owner decisions before anyone changes the plant network.

OT/IT network segmentation for manufacturers (OT means the systems that run machines on the plant floor) separates the office network from the network that runs production equipment, so a problem on one side cannot automatically reach the other. TechProComp, a Texas managed IT provider, provides managed IT services for manufacturing on the office side of that boundary.

What should an owner know first?

Who is this playbook for?

If your IT lead, a customer or an insurer wants the plant network separated from the office network, this playbook is for you. It suits owners and presidents of manufacturers with 80 to 150 employees, and it is written for the person who signs the budget, not the person who configures the firewall. The guidance follows NIST SP 800-82 Rev. 3, the Guide to Operational Technology (OT) Security, final in September 2023.

NIST’s publication page also notes an initial public draft of Revision 4, with comments due November 30, 2026.

What will you be able to do after reading it?

You will be able to approve scope, downtime and budget for network segmentation for manufacturing in plain terms. You will also have ten decisions to answer and eight neutral questions to ask your IT lead or provider.

How can an office ransomware event stop production?

Distaster Recovery Plan Background

On a flat network, one infected office PC may have a route to the machines that run production. A flat network has no enforced boundary between office and plant systems.

Because plant systems may depend on office-hosted services and shared accounts, an office-side ransomware event can stop production on a flat network, so TechProComp recommends firewall-enforced zones that start at the office-to-plant boundary instead of VLANs alone.

What makes a flat network risky?

A flat network puts office PCs, servers and plant equipment in one shared address space, with no enforced rules between them. Any device on it may be able to talk to any other device. That is why one compromised office PC matters to the plant.

The FBI’s 2025 Internet Crime Report names Critical Manufacturing among the sectors most affected by the top ransomware variants that year.

Which dependency paths link the office to the plant?

Four paths may link an office problem to production:

  • Shared address space: office and plant devices sit on one network and can reach each other.
  • Direct routes: an office PC may reach an HMI (the screen operators use to run a machine) or a plant server.
  • Shared domain accounts: one Active Directory login (the system that manages who can sign in) may work on both sides.
  • Office-hosted services: plant systems may depend on ERP (orders and inventory) or MES (work tracking on the floor).

What do the sources say?

EPA guidance for water systems says most attacks on OT networks begin on the IT network. In May 2021, a joint FBI and CISA advisory said Darkside ransomware hit a pipeline company’s IT network, and the company disconnected certain OT systems to keep them safe. Nextgov reported the advisory’s finding of no indications at that time that the Colonial Pipeline attacker moved to OT systems.

So an office-side event can lead a plant to shut systems down as a precaution. These sources don’t prove that any single plant has these dependency paths, so check each path on your own network.

Which zones does a mid-sized plant need?

A mid-sized plant needs four zones: the business network, a controlled boundary, plant-floor supervisory systems, and production cells. This is an owner-level view, not the formal Purdue model.

Business network

What lives here: office PCs, email, ERP (orders and inventory) and Active Directory (Purdue Level 4).

What may cross: only approved requests, such as a production schedule, through the controlled boundary.

Controlled boundary (industrial DMZ)

What lives here: firewalls, a small set of servers that pass data between the two networks, and the path for vendor remote access. This buffer area is also called an industrial DMZ (demilitarized zone).

What may cross: only named requests in each direction, with everything else denied by default. TechProComp’s Cloud Firewall (Firewall as a Service) works on the office side of your network.

Plant-floor supervisory systems

What lives here: HMIs (the screens operators use), SCADA (software that monitors and controls many machines) and the historian (the database that records production data).

What may cross: read-only data going to the office, and approved commands coming from engineers.

Production cells

What lives here: PLCs (the controllers that run a machine), robots and motor controls on one line or cell, closest to Purdue Level 0, the physical process.

What may cross: only the traffic its supervisory systems and maintenance tools need.

What are zones and conduits in plain words?

A zone is a group of equipment with the same risk, and a conduit is the controlled path between two zones. Automation.com describes a zone as a grouping of cyber assets that share the same cybersecurity requirements. The ISA/IEC 62443 series sets requirements for industrial control system security, and ISA’s ISA-95 standard builds on the Purdue model of plant levels.

IEC 62443-3-2 covers how to split a system into zones and conduits and assess the risk of each.

Is a VLAN enough?

Server cloud data storage concept. Cloudscape digital online service for global network. Web database backup computer infrastructure

No. A VLAN is a label that groups devices on a switch so their broadcast traffic stays apart, but only firewall or access-control rules between VLANs enforce separation.

What does a VLAN do?

A VLAN splits one physical switch into several groups, so a broadcast message from one group does not reach another. Think of it as sorting mail into separate trays. The trays aren’t locked, and the VLAN doesn’t decide which group may talk to which.

What makes separation real?

Separation becomes real when a firewall or access rules sit between VLANs and deny traffic by default. EPA guidance says a firewall can deny all connections between OT and IT systems by default. A core switch that routes between VLANs with no rules gives false comfort, because every VLAN can still reach every other.

Ask your IT lead one question: which rules sit between the VLANs, and who reviews them?

What should your IT lead know?

For your IT lead: the separation comes from inter-VLAN ACLs (access control lists on the routing device) or firewall zones with default-deny policies, not from VLAN tags alone. Record each permitted flow by source, destination and port, so the rule set can be reviewed and tested. Start from a deny-all baseline and add only the flows the plant needs.

Which OT/IT network segmentation approach fits a mid-sized plant?

TechProComp recommends firewall-enforced zones for a plant of 80 to 150 employees, with exceptions by risk and budget. The four options range from a cheap base layer to a heavy engineering project, so the right choice depends on what the plant can stop and what it can afford.

A May 2025 federal fact sheet from CISA, FBI, EPA and DOE lists segmenting IT and OT networks, with a DMZ for passing control data to business systems, among its primary mitigations.

How do the approaches compare?

The table rates each approach from low to high for a plant of 80 to 150 employees.

ApproachWhat it protects againstEffortDisruption risk to productionOngoing upkeepTypical fit for an 80 to 150 employee plant
VLAN onlyStray broadcast traffic, but no enforced access controlLowLowLowBase layer only
Firewall-enforced zonesOffice-side threats reaching the plant, with controlled paths onlyMediumMediumMediumBest match for most plants
Cell-level micro-segmentationSpread between machines or cells inside the plantHighHighHighAdd-on for high-risk cells
Full physical separation (air gap)Any network path between the two sidesHighMediumHighNarrow fit, since data moves by hand

How should you read the ratings?

  • What it protects against: the main threat that each option is designed to address.
  • Effort: the amount of engineering work needed to design and set up the option.
  • Disruption risk: the chance that production is affected while the work is under way.
  • Ongoing upkeep: the rule reviews and device maintenance that continue long after launch.
  • Typical fit: how well the option suits a plant of 80 to 150 employees.

These ratings are TechProComp’s judgment, not figures from a standard. The ten owner decisions in this playbook double as a one-page checklist you can print.

Why do IT and plant staff disagree, and what settles it?

IT leans on access control and patching, and plant staff lean on uptime and fast troubleshooting. Both priorities are legitimate. Three written default rules give each side something to work from.

Why do availability and access control pull apart?

NIST SP 800-82 Rev. 3 says OT security objectives typically prioritize integrity and availability, followed by confidentiality. It also treats safety as an overarching priority. That order helps explain why plant teams push for uptime.

When should patches go on?

Our default rule: patch office systems on the normal schedule, and patch plant systems only inside a planned maintenance window that your controls engineer has approved.

Why: a patch that restarts a machine mid-shift stops production, while a patch skipped for good keeps a known gap open.

Who controls remote vendor access?

Our default rule: vendors reach plant equipment only through the controlled boundary, with a named account, a logged session and approval for each visit.

Why: a single controlled entry point gives you one place to approve, record and shut off vendor access. A 2023 joint CISA and NSA guide warns that attackers increasingly co-opt legitimate remote access tools to get into networks.

Who holds admin rights on plant switches?

Thumbnail-For-Zero-Trust Security The Future of Business Cybersecurity-By-TechProComp

Our default rule: the IT lead holds administrator rights on plant switches and firewalls, the controls engineer approves each change that touches production, and both steps are logged.

Why: one named owner plus a second sign-off keeps changes traceable without slowing urgent repairs.

A separate guide covers who owns OT security in detail.

What does working alongside an in-house IT lead look like?

Your IT lead built the network and knows every device and workaround, and that knowledge stays with them. Co-Managed IT adds a TechProComp team around your IT lead for monitoring, helpdesk tickets, backup verification and after-hours response.

Slobo and his team have been a valuable resource for us over the last year filling some knowledge gaps within our IT department. – Keith Kelley on CloudTango

Where should a plant start?

A plant should start at the office-to-plant boundary and at vendor remote access, before any cell-level work. That order keeps the first changes away from the machines that make product.

Why start at the boundary?

NIST recommends a DMZ design with firewalls and logical separation between corporate and OT networks. TechProComp’s recommendation is to build that boundary first, because one boundary covers every route between the office and the plant. Vendor remote access belongs at the same boundary.

That boundary also gives your IT lead one place to test rules before any machine is touched.

When is boundary-first the wrong order?

Boundary-first isn’t a universal sequence. A plant whose safety systems share the office network may need to separate those systems first, and a plant with one high-risk cell may begin there. Your IT lead and your controls engineer should agree on the order, and write the exception down with its reason.

How do you keep production running during the work?

Schedule each change inside a planned maintenance window, get controls-engineer sign-off before the change, and keep a rollback plan for every step. The guide on how to segment without downtime covers a phased rollout.

We recommend logging a new rule before enforcing it, so you can see what would be blocked. Production keeps using the old paths until the new ones are proven.

What sets the cost of segmentation?

Five cost drivers set the price of a segmentation project. TechProComp pricing is a flat fee per client, set by custom quote based on scope, with no per-ticket billing. Scope is the biggest lever on every cost line that follows.

Which cost drivers matter?

Five drivers add up to the total cost of the project:

  • Firewall hardware and licensing: the devices and subscriptions that enforce the rules.
  • Engineering hours: the time that engineers spend to design, build and test the rules.
  • Maintenance-window labor: the technician time spent working while production is paused for the change.
  • Documentation: the written record of zones, rules and permitted traffic that your team keeps after the project ends.
  • Monitoring: the ongoing watch on the new boundary, so unusual traffic gets noticed after launch.

How do you size the downtime side?

Put a dollar figure on an hour of stopped production before you compare quotes. The downtime cost calculator turns that hour into dollars. Compare that figure with the project cost and with the hours of exposure each rollout option leaves open.

What do clients say about estimates?

On top of being a pleasure to work with, their prices were very fair and their estimate gave us an accurate price to keep in mind. – Lucas Christianson on CloudTango

What does segmentation not do?

Segmentation does not stop a threat already inside a cell, does not replace patching or backups, and does not make an old PLC (the controller that runs a machine) secure. Knowing these limits up front keeps expectations realistic for you and your IT lead.

Which limits should an owner expect?

  • A USB stick or a person with local access can bring a threat straight into a cell, a risk NIST SP 1334 covers for portable storage media.
  • Patching and backups still matter, because segmentation limits spread and doesn’t repair a flawed system or restore lost data.
  • An old PLC stays as exposed as before, and the boundary only controls who can reach it.
  • Manual controls still need testing, and the FBI and CISA advisory says to regularly test manual controls so critical functions keep running.

What is TechProComp’s scope?

Techprocomp Team 012

TechProComp works on the network and IT side, alongside your IT lead and your controls engineers. Controls programming and changes to PLCs stay with your controls engineers.

Our Cloud Firewall (Firewall as a Service) and LAN Zero Trust services work on the office side of your network. Your controls engineers lead any controls work, and we coordinate on the network side.

Our work with plants falls under managed IT for manufacturers.

What stands out the most is their exceptional responsiveness and reliability. – Verified User on Clutch

What decisions does the owner need to make?

Ten decisions need an owner’s answer before anyone changes the plant network. Each can be answered without technical help. Settle them in order, because later answers depend on the earlier ones you have already settled.

A May 2025 OT mitigations fact sheet from CISA, FBI, EPA and DOE lists securing remote access to OT networks, including phishing-resistant multifactor authentication, as a primary mitigation.

Can AI flag segmentation rule drift between your reviews?

Tpc App 5

Segmentation only protects the plant while the rules between zones still match what you approved, and that’s why the rule-review decision above matters. Between those reviews, TPC Ops Hub, the platform we built in-house, checks the office side of the boundary against your security baseline. If a firewall setting drifts, the AI flags it and creates a ClickUp ticket immediately, ranked by business impact and escalated with the context already attached. Your IT lead sees the same dashboard our engineers use. The status and history of every flagged change stay visible when your insurer asks or the next rule review comes up. Any fix that touches production still needs your controls engineer’s approval, because the AI raises the flag and people decide what happens next. See what our AI-powered IT support checks between reviews.

Explore AI IT Services

See how our AI spots firewall rule drift on the office side of your plant boundary and turns it into a tracked ticket before your next segmentation review.

Which decisions cover scope and risk?

Answer these first, because they set the size of the project:

  1. Which parts of the plant network are in scope for the first phase?
  2. How many hours of downtime can the plant tolerate, and during which weeks or shifts?
  3. Who approves the budget, and what is the ceiling?
  4. Who is accountable to customers and to you if production stops during the work?
  5. What is the policy for vendor remote access to plant equipment, and who approves each visit?

Which decisions cover proof and follow-through?

Answer these next, because they decide how you will know it worked:

  1. What logs will we keep for the plant network, and who reviews them?
  2. What does our insurer need us to confirm?
  3. What is the timeline for each phase, and who owns each milestone?
  4. How will we measure whether the project worked once it is finished?
  5. How often will we review the firewall rules and the access list?

Write each answer down with a name and a date, so every decision has an owner.

What should you ask your IT lead or provider?

Eight neutral questions treat your IT lead as a partner and give you answers you can act on. Your IT lead knows the plant network better than anyone else in the building, and these questions ask for that knowledge. They also give you a record of what was agreed.

Which questions cover changes and access?

Ask these first, because they decide who can change the plant network:

  1. Which changes need controls-engineer sign-off before we make them?
  2. What do we keep admin access to?
  3. Which vendors have remote access today, and how is each session approved?
  4. What is the plan if a change affects a machine during a shift?

Which questions cover proof and ownership?

Ask these next, because they show how the work will be checked and supported:

  1. What documentation will we receive when the work is done, and who keeps it?
  2. How do we roll back each change if something breaks during a maintenance window?
  3. Which logs show who did what on the plant network, and how long are they kept?
  4. Who gets the first call when production stalls, and who comes second?

Share the questions with your IT lead before the meeting, so the answers come from preparation and not from surprise.

Frequently Asked Questions

What is OT/IT network segmentation in a manufacturing plant?

OT/IT network segmentation divides a manufacturer’s office network from the network that runs production equipment, then controls what may pass between them. The goal is that a problem on one side, such as ransomware on an office PC, cannot automatically reach the other. Firewall rules between the two sides do the enforcing.

Why can an office ransomware infection stop a production line?

It can when plant systems share a flat network with office systems or depend on office services such as logins, ERP or MES. Ransomware that spreads across that network or locks those services may leave machines without data or access. Operators may also disconnect plant systems as a precaution, which stops production too.

Is a VLAN enough to segment a plant network?

No. A VLAN groups devices, but traffic can still cross between VLANs unless a firewall or access rules block it. Enforcement comes from the rules between VLANs, so ask your IT lead which rules exist, which traffic they allow, who reviews them, and how a change to them gets approved.

What is the Purdue model and do mid-sized manufacturers need it?

The Purdue model describes plant systems in levels, and ISA-95 builds on it with five levels, from Level 0 (the physical process) to Level 4 (business activities). A mid-sized manufacturer doesn’t need the full model. A four-zone view gives you enough to decide scope and budget, and your IT lead can add formal levels later if needed.

What is the difference between network segmentation and an air gap?

An air gap means no network connection between two systems, so data moves by hand. Segmentation keeps the connection and controls it with firewall rules, which lets approved data flow between office and plant. A plant that exchanges data with ERP or MES systems needs that controlled connection, which a true air gap can’t provide without manual transfers.

What is a zone and conduit design in IEC 62443?

A zone is a group of equipment with the same risk, and a conduit is the controlled path between two zones. The ISA/IEC 62443 series sets requirements for control system security, and IEC TS 62443-1-1 covers its terminology, concepts and models. Your IT lead can confirm which part of the series applies to your plant.

Does a mid-sized manufacturer need an industrial DMZ?

In TechProComp’s view, yes, in some form, and we recommend it for plants of 80 to 150 employees. An industrial DMZ is a buffer area between the office and plant networks where firewalls filter traffic. Even a small plant benefits from one controlled place where office-to-plant traffic passes, and vendor remote access should connect there too.

Where can you read next?

Key Terminology

OT

OT (operational technology) is the set of systems that run machines on the plant floor, such as PLCs, robots, motor controls and the screens operators use. It differs from IT, which runs the office. OT systems are built to keep production running.

Flat network

A flat network is one where office and plant devices share one address space with no enforced rules between them. Any device may be able to reach any other. Segmentation replaces that with zones and controlled paths.

Zone and conduit

A zone is a group of equipment that shares the same risk and security needs. A conduit is the controlled path between two zones. Each conduit lists what traffic may cross and who approves changes.

Industrial DMZ

An industrial DMZ (demilitarized zone) is a buffer area between the office and plant networks. Firewalls there monitor and filter traffic, and connections pass through it instead of going straight across.

Purdue model

The Purdue model describes plant systems in levels. ISA-95 builds on it with five levels, from the physical process at Level 0 to business activities at Level 4. This playbook uses a shorter four-zone view for owners.

Micro-segmentation

Micro-segmentation applies firewall rules inside the plant, between individual cells or machines. It limits spread within production but takes more engineering and upkeep than a boundary. It usually comes after the boundary work.

Book a free IT assessment. We’ll review your current office network setup and show you where the gaps are, with no obligation. You can also estimate your downtime cost first.


About the author

Slobodan Krsmanovic, the CEO of TechProComp, brings over 25 years of deep-rooted experience in the IT industry. As the author driving our insightful posts, Slobodan embodies a steadfast commitment to client-centric service, fostering respectful and secure collaborations across all business scales.